Products Description

TheAgricultural Irrigation Volute Diesel Water Pump HW mixed-flow pump is a slant-flow type impeller pump that combines the working principles of centrifugal pumps and axial-flow pumps. Its specific speed ranges from 300 to 500. The flow rate is greater than that of centrifugal pumps but less than that of axial-flow pumps. The head range is 3 to 20 meters. It is suitable for transporting clear water and liquids with similar physical and chemical properties, with a temperature not exceeding 50℃. This pump adopts a horizontal single-stage single-suction cantilever structure, featuring high efficiency, stable shaft power, and good anti-suction erosion performance. It is widely used in farmland irrigation, industrial wastewater treatment, and urban water supply and drainage fields.
Agricultural Irrigation Volute Diesel Water Pump
High efficiency and energy saving: The efficiency is significantly improved compared to traditional HB type pumps.
Stable operation: The fluctuation of shaft power is small and the cavitation margin is low.
Extensive scalability: The performance parameters can be adjusted by replacing the impeller.
Agricultural Irrigation Volute Diesel Water Pump It is composed of components such as the pump body, pump cover, impeller, pump shaft and bearing housing. Among them, medium and small-sized pumps mostly adopt a horizontal structure, featuring small size, light weight, and convenient installation and maintenance.

Product model
| capacity Q | head | suction | rotating speed |
self priming |
power(Kw) | ||
| m 3 /h |
(L/s) | (m) | (m) | (r/min) | (min/5m) | absorbed power |
motor power |
| 3.2 | 0.9 | 20 | 6.5 | 2900 | 1.9 | 0.46 | 1.1 |
| 3.2 | 0.9 | 32 | 6.5 | 2900 | 1.8 | 0.8 | 1.5 |
| 6.3 | 1.8 | 20 | 6.5 | 2900 | 1.9 | 0.87 | 1.5 |
| 10 | 2.8 | 40 | 6.5 | 2900 | 1.5 | 2.7 | 4 |
| 12.5 | 3.5 | 32 | 6.5 | 2900 | 1.5 | 2.1 | 3 |
| 12.5 | 3.5 | 50 | 6.5 | 2900 | 1.4 | 4.3 | 5.5 |
| 15 | 4.2 | 60 | 6.5 | 2900 | 1.3 | 6.2 | 7.5 |
| 20 | 5.6 | 7.5 | 6.5 | 2900 | 1.3 | 9.8 | 11 |
| 30 | 8.3 | 15 | 6.5 | 2900 | 2 | 1.9 | 3 |
| 25 | 6.9 | 32 | 6 | 2900 | 1.5 | 4.4 | 5.5 |
| 35 | 9.7 | 13 | 6 | 2900 | 3.4 | 1.9 | 3 |
| 43 | 12 | 17 | 6 | 2900 | 1.8 | 3.1 | 4 |
| 50 | 13.9 | 32 | 6 | 2900 | 1.5 | 6.8 | 7.5 |
| 60 | 16.7 | 55 | 6 | 2900 | 1.5 | 15 | 18.5 |
| 60 | 16.7 | 70 | 6 | 2900 | 1.2 | 20.1 | 22 |
| 100 | 27.8 | 20 | 6 | 2900 | 1.8 | 7.8 | 11 |
| 70 | 19.4 | 75 | 6 | 2900 | 1.8 | 24.3 | 30 |
| 170 | 47.2 | 55 | 5 | 2900 | 1.8 | 39.2 | 45 |
| 400 | 111.1 | 32 | 5 | 1450 | 2 | 52.1 | 55 |
| 280 | 77.8 | 63 | 5 | 1450 | 1.5 | 73.9 | 90 |
| 400 | 111.1 | 50 | 5 | 1450 | 2 | 80 | 90 |
Application scenario

Agricultural irrigation
The HW mixed-flow pump has a large flow rate (up to 5000 m³/h) and a moderate head (3 - 20 meters), making it suitable for precise irrigation of large areas of farmland in plain regions. Through an intelligent control system, it can achieve on-demand water supply, thereby improving the efficiency of water resource utilization.
Urban and industrial water supply and drainage
This pump is suitable for the construction of urban drainage networks and can handle sewage containing solid particles, with relatively low maintenance costs. In the industrial sector, it is often used for circulating water supply in cooling systems, such as in scenarios like power plant cooling circulation.
Flood prevention and drainage
The HW type mixed-flow pump has the ability to resist blockages, starts quickly, and can be put into use promptly in situations such as urban flooding caused by heavy rain or river flood control, effectively alleviating the problem of water accumulation.
Special condition adaptation
By changing the material of the impeller and the sealing method, it can be adapted to special scenarios such as mine drainage (wear-resistant) and seawater circulation (corrosion-resistant), and can be used for liquid transportation within a temperature range of ≤ 50℃.
Product Introduction
1. Structural Characteristics
The HW type mixed-flow pump is mainly composed of the pump body, impeller, shaft, bearings, and sealing devices. The pump body is usually made of cast iron or welded steel plates, with a reasonable internal flow channel design that can reduce hydraulic losses. The impeller is of mixed-flow type, with blade shapes lying between those of centrifugal pumps and axial-flow pumps, combining the advantages of both. The shaft is made of high-quality carbon steel or stainless steel to ensure strength and corrosion resistance. The bearing part usually uses rolling bearings or sliding bearings, and the sealing device adopts mechanical seals or packing seals to prevent liquid leakage.
2. Working Principle
When the hw type mixed-flow pump is operating, the liquid enters the impeller through the inlet and gains energy under the rotation of the impeller. Due to the special design of the impeller, the liquid is subjected to both centrifugal force and axial thrust, thus forming a mixed-flow motion. After passing through the impeller, the liquid enters the guide vane or the pump casing, where its kinetic energy is further converted into pressure energy, and finally is discharged from the outlet. This working mode enables the hw type mixed-flow pump to maintain high efficiency within a wide range of flow rates.
3. Performance Parameters
The performance parameters of the hw type mixed-flow pump mainly include flow rate, head, power and efficiency. The flow rate range is usually between several hundred cubic meters per hour and several thousand cubic meters per hour, and the head is generally between 5 meters and 20 meters. The power varies according to the different flow rate and head, and the efficiency can usually reach over 80%. When choosing, users need to match the performance parameters according to their actual needs to ensure the efficient operation of the pump.
4. Application Scenarios
The HW type mixed-flow pump is suitable for various applications:
(Agricultural Irrigation: Water supply for farmlands and orchards, capable of meeting the requirements of high flow rate and low head pressure.)
(2) Industrial water supply: Performs exceptionally well in the circulating water systems and cooling water transportation of factories.
(3) Urban Drainage: Suitable for scenarios such as rainwater discharge and sewage treatment, with strong adaptability.
(4) Water conservancy projects: They are also widely applied in areas such as river channel improvement and water diversion from reservoirs.
5. Installation and Commissioning
When installing the hw type mixed-flow pump, the following points should be noted:
(1) The foundation should be stable to avoid excessive vibration.
(2) The import and export pipes should be designed with as few bends as possible to minimize water loss.
(3) The coupling between the motor and the pump needs to be aligned, with the error controlled within the allowable range.
(4) Before the first startup, check that the steering is correct and ensure that the pump is fully filled with liquid.
During the debugging process, the load should be gradually increased, and the operation status should be observed to ensure there is no abnormal vibration or noise.
6. Maintenance and Care
To ensure the long-term stable operation of the HW type mixed-flow pump, regular maintenance is required:
(1) Check the lubrication condition of the bearings and replenish or replace the lubricating oil in a timely manner.
(2) Regularly remove impurities from the pump to prevent the impeller or the flow channel from getting clogged.
(3) Inspect the sealing device. If any leakage is detected, deal with it promptly.
(4) When the pump is to be out of service for a long time, the liquid inside the pump should be drained to prevent rusting.
7. Common Faults and Solutions
The hw type mixed-flow pump may encounter the following problems during use:
(1) Insufficient flow: This might be due to wear of the impeller or blockage at the inlet. It is necessary to inspect and clean.
(2) Excessive vibration: This might be caused by damaged bearings or an unstable foundation. In such cases, the bearings should be replaced or the foundation reinforced.
(3) Motor overload: This could be due to excessive head or blockage of the impeller. Adjust the operating conditions or clean the impeller as necessary.
(4) Sealing leakage: This might be due to the aging of the sealing components, and the sealing device needs to be replaced.
8. Model Selection Suggestions
When choosing a hw type mixed-flow pump, the following factors need to be considered:
(1) Ensure that the actual flow rate and head requirements are neither too large nor too small.
(2) Regarding the properties of the liquid, if it contains particles, a wear-resistant material should be selected.
(3) Environmental conditions, such as temperature and humidity, have an impact on the equipment.
(4) Operating costs, including energy consumption and maintenance expenses.
9. Development Trends
With the advancement of technology, the HW type mixed-flow pump is evolving towards higher efficiency, energy conservation and intelligence. The use of new materials has enhanced its wear resistance and corrosion resistance, and the optimized design has further reduced energy consumption. Some products now have remote monitoring capabilities, making it convenient for users to monitor the operating status in real time.
The hw type mixed-flow pump, as a mature and reliable fluid transportation equipment, plays a significant role in various fields. Understanding its structure, principle and maintenance methods is beneficial for users to better utilize and maintain the equipment, thereby extending its service life.
Our address
Baoding Cloud Center, Hebei, China
Phone Number/whatsapp
+86 18626366701
postmaster@jovidiapump.com

Hot Tags: agricultural irrigation volute diesel water pump, China agricultural irrigation volute diesel water pump manufacturers, water pump sample control, water pump testing control, water pump trial control