Products Description

high flow centrifugal pumps It is mainly used for transporting corrosive liquids without solid particles or media that cannot be contaminated. Its temperature range is generally -20℃ to 105℃, and with special measures, it can reach 180℃. This pump adopts a rear-opening structure design, which is convenient for rapid maintenance. The main components include the pump body, impeller, shaft, pump cover, etc. The performance parameters cover a flow rate of 6.3 to 400 m³/h, a head of 5 to 125 meters, and a temperature range of the transported medium from -20℃ to 105℃. With special measures, it can reach 180℃. Its efficiency is on average 5% higher than that of the F-type pump.
high flow centrifugal pumps With an axial suction and radial discharge structure, the main components include:
The pump body and pump cover form the flow passage part
The closed impeller achieves efficient centrifugal transportation
The rear door structure facilitates maintenance
The suspension components support the shaft system
This pump has a simple structure, reliable performance, small size, light weight, good corrosion resistance, low power consumption, and is easy to use and maintain.
The IH type stainless steel chemical centrifugal pump has wide versatility, with a full range of 140 specifications, but only four types of shafts; for the same specification of shafts, bearings, shaft seals, and fasteners of the impeller can all be interchangeable; the suspension price of the full range of pumps is only four types.
The pump speed is divided into two types: 2900 rpm and 1450 rpm.
Performance: 2900 rpm 1450 rpm
Maximum flow rate: 240 cubic meters per hour 400 cubic meters per hour Maximum total head: 125 meters 55 meters
Maximum speed: 3500 rpm (when using 60Hz power supply, the diameter of the impeller is all reduced)
Maximum working temperature: 160 degrees Celsius
Allowable suction pipeline pressure: 0.3 MPa. The maximum operating pressure of the pump is 1.6 MPa.

Product parameters
| Pump type | Capacity(m3/h) | Head(m) | Motor power(kw) | Speed(r/min) |
| IH50-32-125 | 7.5 | 23 | 2.2 | 2900 |
| IH50-32-160 | 7.5 | 34.5 | 3 | 2900 |
| IH50-32-200 | 7.5 | 51.8 | 5.5 | 2900 |
| IH50-32-250 | 7.5 | 82 | 11 | 2900 |
| IH65-50-125 | 15 | 21.3 | 3 | 2900 |
| IH65-50-160 | 15 | 34.2 | 5.5 | 2900 |
| IH65-40-200 | 15 | 53.2 | 11 | 2900 |
| IH65-40-250 | 15 | 81.2 | 15 | 2900 |
| IH65-40-315 | 15 | 126.8 | 30 | 2900 |
| IH80-65-125 | 30 | 23.2 | 5.5 | 2900 |
| IH80-65-160 | 30 | 36 | 11 | 2900 |
| IH80-50-200 | 30 | 55.2 | 15 | 2900 |
| IH80-50-250 | 30 | 84 | 30 | 2900 |
| IH80-50-315 | 30 | 128 | 48 | 2900 |
| IH100-80-125 | 60 | 23.7 | 11 | 2900 |
| IH100-80-160 | 60 | 37 | 15 | 2900 |
| IH100-65-200 | 60 | 56 | 22 | 2900 |
| IH100-65-250 | 60 | 88 | 37 | 2900 |
| IH100-65-315 | 60 | 132 | 75 | 2900 |
| IH125-100-200 | 120 | 61 | 45 | 2900 |
| IH125-100-250 | 120 | 90 | 75 | 2900 |
| IH125-100-315 | 120 | 132.5 | 110 | 2900 |
| IH125-100-400 | 60 | 52 | 30 | 1450 |
| IH150-125-250 | 120 | 24.8 | 30 | 1450 |
Application scenario

Mainly serving industries such as chemical engineering, petroleum, metallurgy, power, papermaking, food, pharmaceuticals, environmental protection, wastewater treatment and synthetic fibers, it is used for transporting corrosive liquids (such as acids and alkali solutions) and similar water-based media. It is also widely applied in fields like wastewater treatment and synthetic fiber production.
Suitable for clear water, seawater, and chemical medium liquids with acids and alkalis, as well as general paste-like slurries (with a medium viscosity of ≤ 100 centipoise and a solid content of less than 30%)
Precautions for Using Mechanical Seals
The IH type stainless steel chemical centrifugal pump can be equipped with different types of mechanical seals according to different usage conditions (such as internal single-end face balanced and unbalanced type, double-end face balanced type and non-balanced type, external mechanical seal, etc.). Depending on the selected seal type, the usage methods and precautions also vary. The following only lists a few general precautions.
1. Since mechanical seals are generally suitable for use in clean, non-hydraulic particle-containing media, the newly installed pipeline system and liquid storage tank should be thoroughly rinsed to prevent solid impurities from entering the seal end faces and causing the seal to fail.
2. In media prone to crystallization, attention should be paid to frequent rinsing when using mechanical seals. After stopping and restarting, the crystallization on the mechanical seal should be cleaned thoroughly.
3. When disassembling the mechanical seal, it should be done carefully. Do not use hand hammers or iron tools to strike to avoid damaging the sealing surfaces of the moving and static rings.
4. If the dirt cannot be removed, try to clear it and then disassemble it after rinsing to avoid damaging the sealing elements.
5. Before installing the mechanical seal, check if all sealing elements are faulty or damaged. If so, repair or replace them.
6. Strictly inspect the relative friction sealing surfaces of the moving ring and the static ring. No minor scratches, bruises, or other defects are allowed. All components, including the pump body, impeller, and sealing chamber, should be rinsed clean before assembly. Especially the sealing surfaces of the moving and static rings, they should be wiped clean with a clean, soft cloth or cotton yarn, and then coated with a layer of clean grease or engine oil.
7. Pay attention to eliminating deviations during assembly. When tightening the screws, do it evenly to avoid skewing and causing the seal to fail.
8. Correctly adjust the compression amount of the spring. After the pump is installed, when the rotor is turned by hand, it should be felt that the sealing spring has a certain compression amount and can rotate smoothly without a tight feeling. If it feels too tight or cannot be turned, it should be appropriately loosened.
9. For mechanical seals with external flushing, before starting, turn on the flushing liquid to fill the sealing chamber. When stopping, turn off the flushing liquid first and then stop the pump.

Our address
Baoding Cloud Center, Hebei, China
Phone Number/whatsapp
+86 18626366701
postmaster@jovidiapump.com

Hot Tags: high flow centrifugal pumps, China high flow centrifugal pumps manufacturers, water pump sample control, water pump testing control, water pump trial control