Big Capacity Split Casing Water Pump
video
Big Capacity Split Casing Water Pump

Big Capacity Split Casing Water Pump

Send Inquiry
Description
Big Capacity Split Casing Water Pump

 

Big capacity split casing water pumps are double suction water pumps and are use to pump clean water or similar liquids in physical and chemical properties. It can handle heavy sand and mud water or various corrosive after changing the pump construction and materials. The temperature of the pumped liquid should not be exceeded 80℃. And the pumps are mainly suitable for water supply in factories, mines, chemical industry, petroleum, cities, hydropower stations, various conservancy projects and irrigation in farms etc.

The model of pump represents the meaning

 

300S-58A

300:Diameter of suction (mm)

S:Single-stage double-suction split case centrifugal pump

58:Head (m)

A:Impeller cut via the first time

Big Capacity Split Casing Water Pump2
Big Capacity Split Casing Water Pump4

Construction Description

 

The suction and discharge of the pump are both under the centerline of the pump shaft, they are vertical to the shaft centerline and go to horizontal direction. You need not dismount the motor and the outlet and inlet pipes for repairing.

Main parts of pump: pump casing, pump cover, impeller, shaft, double suction seal ring, shaft sleeve,bearing etc. They are made of cast iron except the shaft material being made of fine carbon steel.We can according to user's requirement to adopt the other material.

The impeller working house is composed of pump casing and pump cover. The threaded holes for installing the vacuum meter and pressure meter are separately located at the suction flange and the discharge flange. At the bottom of the suction or discharge flange there is a threaded hole for drain.

The impeller working house is composed of pump casing and pump cover. The threaded holes for installing the vacuum meter and pressure meter are separately located at the suction flange and the discharge flange. At the bottom of the suction or discharge flange there is a threaded hole for drain.

 

The impeller have been done static balance test. It is fixed on the shaft by the shaft sleeves and the shaft sleeve nuts, which axial position can be adjusted by the sleeve nuts. The symmetrical distribution of the impeller to balance the axial force of the impeller.
The pump shaft is supported by two single radial ball bearing. The bearing fitted on the ends of the pump casing is installed in the bearing body and is lubricated by Ca-base grease. The double suction seal ring is used to reduce the leaking water from the pressure water house which would flow back to the suction water house.
Big capacity split casing water pump is driven by the motor through the flexible coupling. It also can be driven by diesel engine if it is necessary.
The shaft seal is packing seal. The packing ring is installed between the packing in order to prevent air leaking into the pump and cooling lubrication sealing, and while the pump working, there is a little high pressure water going through into packing cavity by the groove on the horizontally split face of the pump cover,function as water seal.
The mechanical seal depend on user's requirements.

Big Capacity Split Casing Water Pump3

 

Sectional Drawing

 

Double suction water pump1

 

1.Round nut

2.Bearing house B

3.Bearing ring

4.bearing gland B

5.Water deflector

6.Pump casing

7.Pump cover

8.Double suction seal ring

9.Impeller

10.Shaft sleeve

11.Packing bush

12.Packing

13.Packing ring

14.Shaft

15.Shaft sleeve nut

16.Bearing gland A

17.Bearing hold-down ring

18.Bearing

19.Bearing house A

20.Coupling

 

 

Table of standard Performance

 

Pump model

Capacity

Q

(m3/h)

Head

H

(m)

Speed

n

(r/min)

Power P(kw)

Efficiency

η

(%)

(NPSH)

r

(m)

Impeller

diameter

(mm)

Pump

weight

(kg)

Shaft

power

Motor

power

250S24

(10Sh-13)

360

485

576

27

24

19

1450

33.1

37.2

36.7

45

80

85

81

3.8

Φ285

370

250S24A

(10Sh-13A)

342

414

482

22.2

20.3

17.4

1450

25.8

27.6

28.6

37

80

83

80

3.8

Φ280

370

250S14

(10Sh-19)

360

485

576

16

14

11

1450

19.8

23.1

28.7

30

79

80

60

3.8

Φ270

340

250S14A

(10Sh-19A)

320

432

504

13.7

11

8.6

1450

15.5

16.6

20.3

22

77

78

58

3.8

Φ247

340

300S90

(12Sh-6)

590

790

936

93

90

82

1450

202

243

279

315

74

79.6

75

4.2

Φ531

840

300S90A

(12Sh-6A)

576

756

918

86

78

70

1450

190

217

247

280

71

74

71

4.2

Φ500

840

300S90B

(12Sh-6B)

540

720

900

72

67

57

1450

151

180

200

220

70

73

70

4.2

Φ470

840

300S58

(12Sh-9)

576

790

972

63

58

50

1450

131.7

148.5

165.5

200

75

84

80

4.8

Φ435

809

300S58A

(12Sh-9A)

529

720

893

53

49

42

1450

100.4

118.6

131

160

76

81

78

4.8

Φ410

809

300S58B

(12Sh-9B)

504

684

835

47.2

43

37

1450

88.7

104

111.4

132

73

77

75.5

4.7

Φ390

809

300S32

(12Sh-13)

612

790

900

36

32

28

1450

73.1

81

84.7

110

82

85

81

4.8

Φ348

709

300S32A

(12Sh-13A)

551

720

810

31

26

24

1450

58.1

61.4

68

75

80

83

78

4.8

Φ324

709

300S19

(12Sh-19)

612

790

935

22

19

16

1450

45.9

47.5

47.9

55

80

86

85

5.2

Φ293

487

300S19A

(12Sh-19A)

504

720

829

20

16

13

1450

38.7

39.2

39.1

45

71

80

75

5.2

Φ268

487

300S12

(12Sh-28)

612

790

900

14.5

12

10

1450

30.2

30.4

33.1

37

80

84.8

74

5.5

Φ251

660

300S12A

(12Sh-28A)

522

684

792

11.8

10

8.7

1450

23.3

23.9

24.7

30

72

78

76

5.5

Φ251

R122

660

product-674-672

Hot Tags: big capacity split casing water pump, China big capacity split casing water pump manufacturers, split casing water pump for renewable energy industry, split casing water pump for geothermal power plants, split casing pump for indoor use, medium pressure split casing water pump, corrosion resistant split casing water pump, split casing water pump for brazing

Send Inquiry

(0/10)

clearall